Appendix A4. Combined Waste Formula  


Latest version.
  • Combined Waste Stream Formula

    Alternative limit calculation; for the purposes of these formulas, the "average daily flow" means a reasonable measure of the average daily flow for a 30-day period.

    Alternative concentration limit:

    82-App-01.png

    CT

    = the alternative concentration limit for the combined waste stream.

    C i

    = the categorical Pretreatment Standard concentration limit for a pollutant in the regulated stream I.

    F i

    = the average daily flow of the stream I to the extent that it is regulated for such pollutant.

    F D

    = the average daily flow from (a) Boiler blow down streams, non-contact cooling streams, storm water streams, (b) sanitary waste streams, © process waste streams exempted from Categorical Pretreatment Standards.

    F T

    = the average daily flow through the combined treatment facility (includes F i , F D , and unregulated streams).

    N

    = the total number of regulated streams.

    Alternative mass limit:

    M T

    = the alternative mass limit for a pollutant in the combined waste stream.

    M i

    = the categorical Pretreatment Standard mass limit for a pollutant in the regulated stream 1 (the categorical pretreatment mass limit multiplied by the appropriate measure of production).

    82-App-02.png

    F i

    = the average flow of stream I to the extent that it is regulated for such pollutant.

    F D

    = the average daily flow through the combined treatment facility (includes F i , F D , and unregulated streams).

    N

    = the total number of regulated streams.

(Res. No. 06-1167, 11-15-06)