Fulton County |
Code of Ordinances |
Chapter 34. HEALTH AND SANITATION |
Article XII. SWIMMING POOLS AND NATURAL BATHING PLACES |
§ 34-584. Diving areas and equipment.
(a)
Dimensions. Dimensions (width, depth and length) of the diving area shall be in accordance with anticipated use by divers and with the applicable sanctioning organization recognized and approved by the board of health. The dimensions shall comply with the requirements as stipulated in section 34-607, "minimum dimensions for diving areas of pools", and section 34-608, "minimum water envelopes", or diving equipment manufacturer, whichever is greater.
(b)
Clearance. Diving boards or diving platforms must be installed no less than ten feet apart (edge to edge) and no less than ten feet from any pool side wall, or in accordance with the manufacturer's specifications, whichever is the greater distance. At least 15 feet of free, unobstructed clearance shall be provided above diving boards and diving platforms.
(c)
Finish and use. Diving boards and platforms shall have a light colored, slip-resistant finish. Starting platforms shall be used only for competitive swimming or training purposes shall have a light-colored, slip-resistant finish, and shall be removed from the deck when not being used for their intended purpose.
(d)
Safety. Approved diving equipment shall be installed only on pool types that are equal to or larger than the pool type designated by the manufacturer. Diving equipment shall be installed according to the manufacturer's instructions and specifications and this article. All diving stands higher than 21 inches measured from the deck to the top of the secured end of the board shall be provided with stairs and/or a ladder. Steps and ladders shall be of corrosion-resistant material, easily cleanable and with treads that are slip-resistant and self-draining. Platforms and diving equipment of one meter shall have dual with guardrails that shall be at least 30 inches above the diving board or platform surface. All platforms or diving equipment higher than one meter shall have dual guardrails that are approximately 18 inches from the bottom rail and 36 inches from the top rail above the diving board or platform surface. All platform or diving equipment greater than one meter in height shall have dual guard rails installed at a maximum of one meter above the deck level and continuous above the board or platform, and in accordance with manufacturer's specifications. All required guardrails for diving platforms/boards shall extend over to at least the edge of the pool wall. Diving equipment shall be permanently anchored to the pool deck. A sign stating "Only one user allowed on diving board, platform or ladder at any time" shall be posted at the base of access to the diving board.
(Ord. No. 09-0120, 1-7-09; Ord. No. 18-0340, Att. A, 5-16-18)