§ 34-578. Sand filters.
(a)
Appurtenances. Each filter tank shall have an access port for inspection and servicing. Each filter shall have both influent and effluent pressure gauges with a minimum face size of two inches. The filter system shall have an adequately sized, in-line backwash sight glass on the backwash line. All appurtenances shall be conspicuously located for quick inspection.
(b)
Piping and valves. The filtering system shall be designed with all valves and piping required that allows filtering to pool, filtering to waste, filter bypass to waste, and complete drainage of the system. The piping layout shall accommodate proper maintenance, operation and inspection.