§ 34-525. Tables.
TABLE A
MANDATORY CONNECTION CRITERIA—
COMMERCIAL DEVELOPMENTMaximum Anticipated
Average Daily Sewage
Flow
(gpd)Distance to Public or Commercial Sewerage System
(feet)× ≤ = 1,000 500 1,000 < × ≤ = 3,000 1,000 3,000 < × ≤ = 6,000 1,500 × > 6,000 2,000 (Res. of 9-7-88(3), § 30-2-7, table A; Ord. No. 18-0340, Att. A, 5-16-18)
TABLE B
MANDATORY CONNECTION CRITERIA—
RESIDENTIAL DEVELOPMENTNumber
of LotsDistance to Public
or Community
Sewerage System
(feet)6 ≤ = × ≤ = 25 1,000 25 < × ≤ = 50 1,500 × > 50 2,000 (Res. of 9-7-88(3), § 30-2-7, table B; Ord. No. 18-0340, Att. A, 5-16-18)
TABLE C
SEPARATION DISTANCE REQUIREMENTS
Reference Item Minimum
Separation
(feet)
Septic TankMinimum
Separation
(feet)
Absorption
FieldBored wells, springs (existing, proposed or abandoned) 50* 100* Drilled wells (existing, proposed or abandoned) 25 50* Suction water lines 50 100 Pressure water lines 10 10** Lakes, ponds, streams, waterways 25 50 Edge of drainage ditch (draw) 15 15 Edge of embankment 15 15 Retaining wall (uphill) 15 15 Retaining wall (downhill) 5 5 Building structure 10 10 Pool wall 10 10 Edge of pavement 5 5 Property line (public water) 10 10 Property line 10 10 (Individual water supplies) 50 50 Retention, detention ponds (100-year pond elevation) 15 15 Illegal trash pits*** 15 15 *Minimum separation distances from the septic tank and absorption field and abandoned wells may be reduced to 25 feet if the abandoned well is filled and compacted (in three-foot layers maximum) with any material approved by the board of health. The top of the abandoned well shall also be sealed and capped as approved by the board of health.
**Pressure water lines may be allowed in the cover over the system but not the absorption field trench if approved by the board of health.
***No trash pits shall be allowed on lots (residential or commercial) where an onsite sewage management system is proposed unless approved by the board of health and the appropriate governmental jurisdiction. Board of health approval of any trash pit shall be limited only to its location relative to the proposed location of the onsite system. See detail B.
(Res. of 9-7-88(3), § 30-2-7, table C; Ord. No. 18-0340, Att. A, 5-16-18)
TABLE D
SEWAGE FLOW SCHEDULE
Type of Establishment Gallons
Per Day
(Unless
Otherwise
Noted)Assembly halls, per seat 3 Boardinghouses, per person 75 Roominghouses, per person 60 Churches, not including assembly halls, classrooms, day care centers, kindergarten, etc., per seat 3 Church classrooms, per person 5 Church kitchen waste, per person (based on dining area) 3 Day care centers and kindergartens, no meals, per child 20 Residence, including independent mobile homes and cottages: see section 34-517 Food service establishments, per customer 13 Add, for cocktail lounge, per customer 2 Retail service, per customer 5 Swimming pools, bathhouse, per bather based on bathing load (see article XII of this chapter entitled "swimming pools") 20 Taverns, bars and cocktail lounges, no meals, per customer 20 Workers/employees, including factory, office, school, commercial and construction, without showers and no industrial waste, per person 25 Workers/employees, including factory, office, school, commercial and construction, with showers and no industrial waste, per person 35 (Res. of 9-7-88(3), § 30-2-7, table D; Ord. No. 18-0340, Att. A, 5-16-18)
_____
TABLE E
MAXIMUM OCCUPANCY
Type of
EstablishmentPerson(s)/Floor Area
(square feet)
Assembly halls No ratio for fixed seating, stated on plans (approved by the fire department), or 1/15 for moveable seating
*Churches, not including assembly halls, day care centers, kindergartens, etc. No ratio for fixed seating, stated on plans (approved by the fire department), or 1/7 for moveable seating
Church classrooms 1/20 Day care centers/kindergartens No ratio for number of children and employees, stated on plans (approved by DHR, day care licensing division, or 1/35, not including employees
*Food service establishments No ratio for fixed seating, stated on plans (approved by the fire department), or 1/15 for moveable seating
Office 1/100 Retail service: Employees 1/1,000 Customers (first floor/ground floor) 1/30 Customers (remaining floors) 1/60 Warehouse/storage 1/300 Maximum occupancies not listed in this table shall be determined in accordance with the Fulton County Fire Department regulations.
*Does not include employees to be identified in the letter of intent and calculated based on the remaining total gross floor area (not deducted in table E) at a ratio of 1:100.
(Res. of 9-7-88(3), § 30-2-7, table E; Ord. No. 18-0340, Att. A, 5-16-18)